—— Analysis of Industrial Dehumidifier Heating Function: How to Achieve Dual Temperature and Humidity Control? ——

In industrial production, warehousing, and specialized process environments, precise control of ambient temperature and 

humidity is critical. Traditional single-function dehumidifiers or heaters often struggle to handle complex and variable operating 

conditions. Industrial dehumidifiers with heating capabilities, however, become essential equipment for maintaining environmental 

stability through integrated dual temperature and humidity control. This article delves into the technical principles behind their 

heating functionality and explores core strategies for coordinated temperature and humidity control.


I. Core Technical Approaches for Heating Functionality

The heating capability of industrial dehumidifiers is not achieved through simple addition of heating modules, but rather through 

organic integration with dehumidification cycles via multiple technical pathways. Primary methods include:

  • Heat Pump Cycle Heating: This represents the most efficient and prevalent technical approach. Based on the reverse Carnot

    cycle principle, the system utilizes the coordinated operation of compressors, evaporators, condensers, and throttling devices

    to extract low-grade thermal energy from the external environment. This energy is elevated through compressor work and

    released as high-grade thermal energy at the condenser side, suitable for air heating. In dehumidification mode, the recovered

    latent heat (heat released during water vapor condensation) combines with the system's inherent heating capacity. This enables

    dehumidification without lowering—and even while raising—air temperature, effectively avoiding the “apparent cooling” effect

    caused by conventional condensation dehumidification.

  • Electric Auxiliary Heating (PTC or Resistance Wire): Serving as an effective supplement or emergency solution for heat pump

    heating,electric auxiliary heating systems offer rapid response and heating capacity unaffected by low temperatures. When

    extremely low ambient temperatures reduce heat pump efficiency or when rapid heating is required, the electric auxiliary system

    activates to ensure the target temperature is quickly reached. However, its energy consumption is relatively high, typically making

    it an auxiliary or adjustment measure.

  • Waste Heat Recovery and Utilization: In certain high-energy-consumption industrial settings, equipment operation or process

    flows generate substantial waste heat. Advanced system designs integrate heat recovery devices—such as utilizing exhaust

    heat from condensers or thermal energy from process cooling water—to redirect this waste heat via heat exchangers for heating

    process air. This approach significantly enhances overall energy efficiency, reduces operating costs, and achieves energy conservation

    and environmental protection.


II. Temperature-Humidity Synergistic Control Strategy

Achieving precise “dual temperature-humidity control” hinges on intelligent synergistic control strategies. This transcends simple 

independent temperature and humidity regulation, instead making comprehensive decisions and system adjustments based on the 

dynamic relationship between environmental parameters and set targets.

  • Dynamic Parameter Sensing and Coupling Analysis: The control system employs high-precision temperature and humidity sensors

    to monitor environmental conditions in real time. Core algorithms analyze the coupling relationship between current temperature

    and humidity (e.g., relative humidity is significantly affected by temperature changes) and calculate deviations from target setpoints.

  • Multi-Mode Intelligent Switching and Composite Operation: Based on real-time data and predefined logic, the control system

    automatically determines the optimal operating mode for equipment:

  • Single Dehumidification Mode: When temperature is comfortable or elevated but humidity is excessively high, the system operates

    at maximum dehumidification efficiency. It may minimize temperature impact by adjusting airflow or utilizing bypass mechanisms.

  • Dehumidification with Heating Mode: During low-temperature, high-humidity conditions, the system activates heat pump heating

    or auxiliary electric heating as needed. This simultaneously dehumidifies and elevates air temperature to prevent excessive cooling.

  • Heating/Temperature Control Mode: When humidity is within target but temperature is insufficient, the system prioritizes heating

    cycles to raise ambient temperature.

  • Humidity Priority/Temperature Priority Strategy: Control priorities can be configured based on process requirements. For example,

    precision manufacturing may adopt “humidity priority” to ensure absolute humidity stability with temperature fluctuations within

    specified limits, while warehousing environments may use “temperature priority” to prevent material freeze damage.

  • Precision Control of Actuators: Control commands finely adjust multiple components—including compressor frequency, electronic

    expansion valve opening, fan speed, electric auxiliary heating power, and damper angle—to achieve real-time balance between

    dehumidification and heating capacity. This minimizes energy consumption while approaching and maintaining target temperature

    and humidity setpoints.


III. The Art of Balancing Under Diverse Conditions

In practical applications, balancing dehumidification efficiency with heating demand depends on specific environmental conditions:

  • High-temperature, high-humidity environments: The focus is on efficient dehumidification. Typically, little to no heating is required

    to compensate for the slight temperature drop caused by dehumidification, with the system prioritizing optimized dehumidification

    energy efficiency.

  • Low-temperature, high-humidity environments: This poses the greatest challenge to dual temperature-humidity control capabilities.

    The system must provide sufficient heat compensation while performing powerful dehumidification to prevent further drops in

    ambient temperature. Here, the heat pump system's low-temperature heating performance, defrosting strategy, and the coordinated

    timing of electric auxiliary heating become particularly critical.

  • Low-temperature, low-humidity environments: The focus shifts to thermal insulation and precise humidity control. Heating functions

    primarily maintain temperature stability, while the dehumidification system operates at low load or intermittently to prevent excessive

    dehumidification.


Conclusion

The heating functionality and dual temperature-humidity control capabilities of industrial dehumidifiers embody the high integration of 

modern environmental control technology. Through the flexible application of multiple technical pathways—including heat pumps, electric 

auxiliary heating, and waste heat recovery—combined with intelligent, real-time data-driven control strategies, they achieve precise, efficient, 

and energy-saving regulation of complex industrial environment temperature and humidity parameters. Understanding the underlying 

technical principles and control logic enables users to select and configure equipment appropriately based on their specific operating 

conditions, thereby ensuring optimized production quality, material storage safety, and energy utilization efficiency.